Welcome to Vantage House suppliers of chocolate machinery,
moulds & equipment We are agents for international companies, providing a range of quality products to suit your production. This website has our FULL online catalogues for you to browse! We are only able to supply addresses in the UK & Ireland. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(Acrobat Reader required to download full version)
Colour
Labelling Of The Electric Cable
Diagram 2 ![]() Diagram 2 Legend: 1. Main Switch 5.Stirring 6.
Water Inlet
Connect
the machine as follows: Electrical Connections
The
machine is supplied with 5m of electric cable without a connection plug and a
suitable plug should be purchased locally to suit your EL supply and fitted in
accordance to the EL colour cable wiring diagram. Connect
the machine and switch on the main switch, item 1. Start the stirring, item
5a, and check that the stirring is rotating clockwise. If rotating
anti-clockwise, change over any two of the electrical phases. Water ConnectionsThe
connecting junctions are intended for use with 10mm tube. On the water inlet, item
6, a nylon reducer is mounted which gives a water supply of 4 litres/min.
This must not be removed. Important:
The water supply must be open when the machine is in use so that the built in
magnet valve can control the water flow. The
water outlet, item 7, has to be connected to a drain tube and it is
essential that this is always an open outlet.
SPECIAL NOTES
If
the chocolate is not satisfactory in temperature or tempering, please observe
the following: The
chocolate
Temperature
adjustment is very dependant upon the particular type of chocolate used and the
qualit~. As a general rule, the temperature should be adjusted to 0,5 ‑ 10
C lower than the temperature stated by the chocolate manufacturer. It is recommended
that the temperature adjustment should only be changed in steps of 0.50 C at a
time. The Cooling water Waterflow
control is by normal water pressure adjusted to 4 lt./ min. A variation of
+/- 50% is permissible, without any notable influence on tempering.
Cooling water temperature is very important for efficient operation of the
tempering cycle. 11°C is recommended. If the chocolate gets over tempered, this
can be caused by the mains cooling water being too cold. This can be corrected
by mounting a thermostatically controlled heater/ mixer valve (not supplied),
and adjusting to 11°C. Should
it take more time to complete a tempering cycle than mentioned in note, the
cause can be that the mains water temperature is too warm. This problem can be
reduced by increasing the water flow. This can be simply achieved by removing
the nylon reducer from the water inlet supply nozzle. Should this not be enough
make one more tempering with the thermostat adjusted to 30°C.
When the heating shows on yellow lamp (2 lights), then adjust the thermostat to
31°C (32 C). Additional
notes
If
the stirring mechanism is not operative when tempering starts, it will start
automatically. If
the stirring motor drive is overloaded it is set to stop automatically. It can
then be re-started after approx. 2 minutes.
The 6T Tempering Curve - View
6T Spares
Diagram 1 - View
|
N°
|
Name: |
|
|
|
300
|
CHOCOLATE
KETTLE |
305
|
Chocolate
kettle top |
307
|
Chocolate
kettle lid |
310
|
Rubber
gasket |
|
311 |
Main
heating element |
|
401 |
Outer
cover |
|
402 |
Top
plate |
|
403 |
Plastic
fillet |
|
500 |
STIRRER |
|
510 |
Stirrer
axle |
|
511 |
Stirrer
bearing |
|
511
a |
Stirrer
bearing, rubber gasket
|
|
512 |
Stirrer
bearing
|
|
1304
f |
Thermostat
sensor
|
|
1000 |
CHOCOLATE
DRAW-OFF TAP
|
N°
|
Name: |
|
|
|
|
1001 |
Knob |
|
1002 |
Arm |
|
1003 |
Spring
holder |
|
1004 |
Spring |
|
1005 |
Closure
disk |
|
1006 |
Bearing |
|
1007 |
Holder
for arm |
|
1008 |
Holder
for heating element |
|
1009 |
Heating
element |
|
1010 |
Funnel
- long 240 mm |
|
1011 |
Funnel
- short 90 mm |
|
1200 |
MOTOR
BOX |
|
1201 |
Magnet
valve complete |
|
1202 |
Magnet
valve spool |
|
1203 |
Stirrer
motor |
|
1204 |
Stirrer
motor gear |
|
1205 |
Ventilator |
|
1400 |
CONTROL
BOX |
|
1401 |
Thermostat |
|
1402 |
Control
light - yellow |
|
1403 |
Contact
- blue |
|
1404 |
Control
light blue |
|
1405 |
Contact
- black |
|
1406 |
Contact
- green |
|
1407 |
Control
light - green |
|
1408 |
Contact
- red |
|
1409 |
Main
switch - control light green |
|
1410 |
Relay
for stirrer motor |
|
1411 |
Thermal
cut-out for stirrer motor |
|
1412 |
Control
relay (yellow plastic) |
Manufacture:
ELIWELL type EWPC 800 T.
Read
the chocolate temperature from the display.
Adjusting
of set point:
Press
"set". Led indicator flashes.
Set
point can now be adjusted up or down.

5
seconds after adjustment, the display turns automatically back showing the
temperature.
For
this thermostat there are the following coded parameters and only 2 of the
parameters ought to be changed.
|
PARAMETER: |
DESCRIPTION: |
ADJUSTED
VALUE: |
|
d1 |
Differential |
+
0,1 |
|
LS1 |
Lower
Set 1 limit |
31 |
|
HS1 |
Higher
set 1 limit |
45 |
|
od |
Output
delay |
0 |
|
CAL
|
Calibration |
. |
|
HC1 |
Heating/Cooling |
H |
|
rp
1 |
Relay
Protection |
r0 |
|
Lf1 |
Led
Function |
D1 |
|
dp |
Decimal
Point |
on |
|
hdd |
Half
digit display |
n |
|
tAB |
Not
adjustable |
. |
LS1:
Lower set limit is adjusted to 31°C = Ready chocolate temperature.
HS1:
Higher set limit is adjusted to 45°C = Melting temperature.
These
2 temperatures are chosen as outer limitation, because it makes the adjustment
for the correct temperature easier. Any value between these 2 extreme points can
be adjusted. If other temperatures are required as extreme points, the
parameters can be changed.
How
to code the parameters:
- Press "set" in more than 4 seconds.
- The first parameter will be shown at the display and led indicator will flash.
-
Change
the parameter change by pressing the Up or Down button.
REMEMBER:
you should only change LS1 and/or HSI.
By
pressing "set" the display will show the adjusted value. This value
can be changed by simultaneously pressing "set" and the “Up” or
“Down” buttons.
After
approx. 20 seconds without any influence, the thermostat returns automatically
back showing the temperature.
The 6T model is manufactured to
require very little maintenance, as are most ChocoMa models.
On this machine:
When required, the exterior may
be cleaned with mild detergents and hot water.
The interior should be cleaned
with hot water only as the slightest amount of detergent will affect the
taste of the chocolate.